磁化水对泡沫混凝土强度和泡沫稳定性的影响
作者单位:
王 婷,工程师,E-mail:529006309@ qq. com
作者简介:
中铁十八局集团建筑安装工程有限公司,天津 300457
摘要:
为了提高泡沫混凝土的强度和泡沫稳定性,分别以 0.65,1.65,2.65m/ s 的流速通过永久磁场 1,5,10 次的磁化水制备 9 种泡沫混凝土,对其进行泡沫稳定性、抗压强度、劈裂抗拉强度试验,并与采用未磁化水的试件进行对比. 试验结果表明:使用磁化水后,泡沫混凝土的泡沫稳定性、抗压强度、劈裂抗拉强度明显提高;水的流速和通过永久磁场的次数是重要的因素;与未磁化的对照组相比,磁化水流速为 0. 65m/ s 和 1. 65m/ s 时,磁化 10 次试件的力学性能最好. 磁化水流速为 2. 65m/ s 时,磁化 1 次试件的力学性能最好.
![](/images/icon-open.png)
English:
In order to improve the strength of foam concrete and the stability of foam, nine kinds of foamconcrete were prepared by magnetized water in permanent magnetic field for 1, 5, and 10 times at theflow rates of 0.65, 1.65, and 2.65m / s, respectively. The foam stability, compressive strength, andsplitting tensile strength tests were carried out on them, and compared with the specimens usingunmagnetized water. The test results show that the foam stability, compressive strength and splittingtensile strength of foam concrete are significantly improved after the use of magnetized water. The flowrate of water and the number of times through the permanent magnetic field are important factors.Compared with the unmagnetized control group, when the magnetized water flow rate is 0.65m / s and1.65m / s, the mechanical properties of the magnetized 10 times specimen are the best, when themagnetized water flow rate is 2.65m / s, the mechanical properties of the specimen magnetized once arethe best.